A-A-50026A
TABLE I. Heat outputs
Size (minimum dry weight) pounds |
Heat output (minimum) |
||
Electric (kilowatt rating) |
Steam 1/ (Boiler horsepower) |
Gas (BTU/hour) |
|
100 |
42 |
8.0 |
225,000 |
110 |
48 |
9.5 |
250,000 |
120 |
Not avail. |
11.0 |
275,000 |
150 |
Not avail. |
12.5 |
380,000 |
170 |
Not avail. |
17.0 |
490,000 |
200 |
Not avail. |
20.0 |
675,000 |
1/ Steam pressure at 125 psig.
2.1.1 Loading door. The loading door shall be made of plastic in accordance with the type XXI of ASTM D 4617 or steel and provided with a latch and door handle. The loading door shall be right-handed unless otherwise specified (see 5.2).
2.1.2 Cabinet. The cabinet shall be made of steel with a minimum thickness of 0.044 inch. The cabinet shall have a 100% baked enamel finish on both the inside and the outside. The color on the outside of the cabinet shall be white, unless otherwise specified (see 5.2). The cabinet shall have leveling legs that can extend a minimum of 1 inch.
2.1.3 Basket/drum. The basket/drum shall be made of galvanized steel unless otherwise specified (see 5.2). The basket/drum (cylinder) diameter and volume shall be as specified in table II.
TABLE II. Cylinder diameter/volume
Size |
Cylinder diameter (inches) (minimum) |
Cylinder volume (cu.ft) (minimum) |
15 |
27 |
5.9 |
20 |
27 |
7.9 |
25 |
27 |
9.2 |
30 |
27 |
9.6 |
50 |
32 |
15.8 |
60 |
34 |
19.7 |
75 |
36 |
22.4 |
100 |
44 |
34.0 |
110 |
44 |
36.0 |
120 |
44 |
38.2 |
150 |
50 |
49.7 |
170 |
51 |
51.2 |
200 |
62 |
65.0 |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744