A-A-50047A
2.1.8 Operation/maintenance manual(s). The dry cleaning unit shall be supplied with a complete set of manuals or a complete manual. The manual(s) shall contain installation instructions including bolting to the floor and all necessary connections or hook-ups, including any required exhaust ventilation, eye lavage, or other engineering control. The manual(s) shall contain complete operational instructions or all machine operations, complete maintenance instructions and schedules, a trouble shooting guide for the unit, a description of the formulas/operations of the dry cleaning units, a wiring diagram of the dry cleaning unit, and figures and parts lists for the unit and major components. The parts lists shall have a part numbers for the ordering of spare/replacement parts. All operation/maintenance manuals shall contain all required safety and health warnings, including manufacturer’s recommendations for wearing of any personal protective equipment (PPE) and any product-unique health hazards.
2.2 Electrical requirements. The dry cleaning unit shall be designed to operate on 208/240 volts, 60 hertz, 3 phase power, or as specified (see 5.2).
2.3 Water connections. Water connections shall be 1/2, 3/4, or 1 inch NPT.
2.4 Steam connections. Steam connections shall be 3/8, 1/2, 3/4, or 1 inch NPT. The steam pressure required shall be no more than 60 pound-force per square inch gauge (psig).
2.5 Air connection. Air connection shall be 1/4 inch NPT. The air pressure required shall be no more than 85 psig.
2.6 Data name plate (Government unique requirement see 5.4). The dry cleaning unit shall be furnished with a data name plate in accordance with the applicable requirements of MIL-STD-130 except the requirements for: Methods of applying; (b) Identification tags; (c) Information not required and (d) Optional marking information shall not apply. The data plate shall be made of minimum 20 gauge corrosion-resisting metal and attached to the unit by rivets, screws, or welding in such a manner as to meet the applicable National Sanitation Foundation sanitary requirements for this equipment. The plate shall contain the following information which shall be stamped, engraved or applied by photosensitive means:
National Stock Number
Procurement Contract Number
Specification Data
Manufacturer’s Name, Address and Telephone Number
Supplier’s Name, Address and Telephone Number (List only if different from
Manufacturer)
Manufacturer’s Model Number
Government Approved Manual Number (when specified, see 5.2)
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business