MIL-L-44142A(GL)
3.6 Performance.
3.6.1 Electrical distribution system. Every end item shall be tested as
specified in 4.6.1. Any test failure shall be cause for rejection of the end
item.
3.6.2 Air distribution system. The air distribution system when operating
for 15 minutes shall not fail and shall show no evidence of the following
conditions when tested as specified in 4.6.2.
a.
Overheated bearings.
b.
Leaks from any part of the system.
c.
Low pressure.
d.
Inoperable valves.
3.6.3 Water distribution system. The water distribution system, the pump,
water lines, and boiler when operating for 15 minutes shall not fail and show
no evidence of the following conditions when tested as specified in 4.6.3.
Leaks from any part of the system.
a.
b.
Low pressure.
c.
Improper operation of water heater and controls.
3.6.4 Washing machine. The washing machine and related equipment shall not
fail or show evidence of the following conditions when tested as specified in
4.6.4.
a.
Improper operation of controls.
b.
Leaks during washing and rinse cycles.
c.
Improper or incomplete operation of pressure controls, air valves,
intake valves, or discharge valves.
d.
Structural failures or failures of welds.
Improper water level.
e.
3.6.5 Extractor machine. The extractor machine when operated shall not
fail and shall show no evidence of the following conditions when tested as
specified in 4.6.5.
a.
Improper operation of controls.
b.
Leaks from any portion of the curb or plumbing.
c.
Structural failures.
d.
Excessive vibration during operation.
6