OO-W-00860E (GSA-FSS)
3.
REQUIREMENTS
3.1 Conformance.
3.1.1 Conformance to UL Inc.Inc.
Electrical appliances shall conform to
UL-560 and UL-1206, as applicable. For 120 volt, 60 hertz appliances,
the UL label or listing mark shall be affixed to the appliance. For
220 volt, 50 hertz appliances, the manufacturer shall provide a
certified test report from a recognized independent testing laboratory
acceptable to the Government, indicating that the appliance has been
tested and conforms to the applicable requirements of the UL standard.
3.1.2 Conformance to ANSI. Gas dryers shall conform to ANSI 221-5.1,
Type I Gas clothes dryer. A Certificate of Compliance shall be
provided to the Government.
3.1.3 Contractor compliance. Compliance with the requirements of
3.1.1 and 3.1.2 shall not absolve the contractor from compliance with
all requirements of this specification.
3.2 Materials.
Materials used in the construction of appliances
shall be as specified herein. When materials are not specified, the
materials shall be of the same quality normally used in the
manufacturer's standard commercial practice for the applicable purpose.
All materials shall be new, unused, and free from any defects or
imperfections which affect appearance, serviceability, or durability.
Asbestos shall not be used as a material in any part of an appliance.
3.2.1 Corrosion-resistant steel.
Corrosion-resistant steel shall be
in accordance with QQ-S-766.
3.3 Design. Appliances shall be in accordance with the contractor's
current production design. All parts subject to wear shall be
accessible for repair, replacement, or adjustment.
3.3.1 Definition of operational cycle. When the term "operational
cycle" is used in this specification, it means a complete functional
cycle. A functional cycle for washers consists of the complete wash,
rinse, and damp dry operation. A functional cycle for dryers consists
of the complete drying operation.
3.3.2 Mounting. When specified (see 6.2), appliances shall contain
provisions for bolting to the floor. Without being bolted to the
floor, appliances shall be capable of completing an operational cycle
without walking or moving on the floor, when tested as specified in
4.4.5.