OO-W-00860E (GSA-FSS)
3.7 Lubrication. Unless otherwise specified (see 6.2), permanent
lubrication shall be provided. When periodic lubrication is required,
all bearings shall be adequately lubricated upon assembly and shall be
mounted so they may be lubricated by normal maintenance procedures.
3.8 Interchangeability. All appliance parts shall be manufactured to
definite standards, tolerances, and clearances in order that any part
of a particular type or model may be replaced or adjusted without
requiring modification.
3.9 Electomagnetic compatibility . When specified (see 6.2),
appliances shall be designed and equipped for electromagnetic
compatibility in accordance with Class III requirements of MIL-STD-461
(see 4.4.6).
3.10 Moisture and fungus-resistant treatment. When specified
(see 6.2), electical components of appliances shall be moisture and
fungus-resistant. They shall be treated with material conforming to
and applied in accordance with the requirements of MIL-V-173 and
MIL-T-152, as applicable.
3.11 Operating instructions. Operating instructions shall be
accurate, complete, clear, and legible. They shall be permanently
affixed to the appliance in accordance with the manufacturer's standard
commercial practice and shall be discernible to the operator.
3.12 Plumbing requirements.
Water inlet hoses shall have
connections to fit standard 3/4 inch hose fitting threads. The hoses
shall be of sufficient length to permit connection to faucets a minimum
of 2 feet to the left or right of the appliance and 42 inches above the
floor. The hoses shall be capable of withstanding the 500 pound
hydrostatic pressure test (see 4.4.2) without any leaks, ballooning, or
other discernible defects. During the test, the ferrule shall not
creep more than 1/16 inch. The drain hose shall have a "U" shaped
discharge end and shall be of sufficient length to permit discharge
into a laundry tub or standpipe positioned a minimum of 6 inches from
either side and 36 inches high. Washers shall be provided with
connections and inlets for hot and cold water and with an outlet for
draining. They shall be furnished with a hose for each of these three
connections and shall be equipped with a pump for draining the tub.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business