MIL-DTL-2211F
3.1 First article. When specified (see 6.2), the supplier shall furnish a sample for first article
inspection and approval (see 4.2 and 6.3).
3.2 Materials. Materials not definitely specified shall be of the quality normally used for the
purpose in commercial practical.
3.2.1 Plywood. Plywood used for the tabletop and battens shall be exterior type, grade A-B,
sanded two sides, conforming to group 1 of Product Standard PS 1.
3.2.2 Aluminum and steel angles and shapes.
3.2.2.1 Aluminum angles. Aluminum angles shall be fabricated of alloy 3003 conforming to the
requirements of ASTM B209.
3.2.2.2 Steel, bar size shapes. Bar size shapes shall conform to ASTM A575 or if formed from
steel sheet or strip shall conform to QQ-S-698.
3.2.3 Hardware. Nuts and bolts, wing nuts, wood screws, washers, rivets, and cotter pins shall be
standard commercial products, fabricated from steel and except for wood screws shall be zinc
plated.
3.2.4 Enamel. Enamel shall be a combination of air-drying and baking enamel that provides a
smooth, semigloss, possessing excellent corrosion-inhibiting properties. The color shall be olive
drab 24084 conforming to FED-STD-595.
3.2.5 Varnish, spar. Spar varnish shall conform to the requirements of MPI # 28.
3.2.6 Adhesive. Adhesive shall be urea-resin-type conforming to ASTM D4690.
3.3 Construction. The construction of all components and assemblies of the item covered by this
specification shall conform to requirements herein and the design, details, dimensions, material
classification and sizes specified on Drawing 5-13-2498.
3.3.1 Top. The top shall be plywood specified in 3.2.1 and sanded smooth.
3.3.1.1 Reinforcing and edging. The top shall be reinforced with steel angles specified in 3.2.2.2
and securely held to plywood top with wood screws. All edges of top shall be protected with
aluminum angles specified in 3.2.2.1, and securely held to plywood top with wood screws.
3.3.2 Battens. The battens shall be plywood specified in 3.2.1 and with all sides and edges
sanded smooth. Battens shall be fastened to plywood top with adhesive specified in 3.2.6 and
securely held in place with wood screws.
3.3.3 Hinges. Angles and channels forming hinges shall be firmly bolted through the battens and
the top with 3/8-inch carriage bolts, countersunk into the top and the nuts tightly drawn against lock
washers.
3.3.4 Legs end braces. The legs, stretchers and braces shall be formed from the steel sheet or
strip specified in 3.2.2.2.
3.3.5 Finish.
3.3.5.1 Plywood. All exposed surfaces of plywood parts shall be cleaned of all dust and dirt.
Exposed plywood shall be coated with spar varnish as specified in 3.2.5, before assembly and with
a sufficient number of coats to produce a uniformly glossy appearance.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business